Friday, 27 March 2009

Disaster Recovery just got "sESXi"



Notes on using vRanger Pro & ESXi for Disaster Recovery


Just succesffully proved vRanger Pro to restore backups taken from Production (ESX 3.5, vRanger Pro on physical with VCB) to infrastructure in DR (ESXi 3.5, vRanger Pro on a VM, non VCB). All this from provisioning DR Infrastructure (ESXi Servers, Storage, vCenter VM) within 1 hour. Silver tier recovery just got "sESXi"!

Infrastructure at Production


  • ESX 3.5 Update 2 on BL460C
  • Storage on 400Gb LUNs presented by IBM SVC
  • VC 2.5 Update 2 VM
  • vRanger 3.8.2.1 & VCB 1.5 & vRanger Pro VCB Plugin 3.0 on Physical DL380 G5 Server
  • VM backups on TSM and replicated to DR

Infrastructure at DR

  • ESXi Update 3 USB on DL360 G5
  • Local Storage
  • VC 2.5 Update 4 VM
  • vRanger 3.2.9.7 & VCB 1.5 & vRanger Pro VCB Plugin 3.0 on W2K3 SP2 VM + .Net Framework 2.0 SP1
Important points to note

If you are running vRanger in a virtual machine to restore workloads backed up by vRanger installed on a physical host, with either traditional LAN based backup or VCB based backup. It is important that the software is installed in the correct order and all the necessary software is installed to enable vRanger to restore both types of backup. If the physical vRanger server performed a backup of a workload using the VCB framework, then you will not be able to restore that workload using another vRanger server unless the VCB framework is also installed. For example, you wish to perform a restore at a DR site.

The correct installation order is
  • Microsoft .Net Framework 2.0 SP1
  • vRanger Pro
  • vRanger Pro VCB Integration module
  • vRanger Pro file-level plugin
  • VMware VCB Framework
Tips
  • Install software in the correct order
  • Create the same directory structure for the VM at the DR site as it is at Production. E.g, if the vRanger working directory is D:\vRanger_Backups at Production, then keep the same directory structure for the vRanger server at DR.
  • This will enable you to first restore the vRanger database (esxRanger.mdb), which then populates the Restore table saving valuable time and effort because you will no longer need to use "Restore from Info"
  • If restoring a vRanger backup that was taken using the VCB framework, then the vRanger server at DR will also need to have the VCB framework installed.

Wednesday, 11 February 2009

Configuring vSwitch0 for Service Console and VMkernel portgroups

Following on from a previous post on how to configure vSwitch0 with active/passive network interfaces using vmware-vim-cmd for the two port groups, I have included some diagrams explaining how it all works.

The reason that Link Aggregation will not give any performance benefit if both the Service Console and the VMkernel share two active uplinks on a virtual switch configured with Route based on IP hash load balancing policy can be summarised as follows.

802.3ad/LACP aggregates physical links, but the mechanisms used to determine whether a given flow of information follows one link or another are critical.

You’ll note several key things in this document that are useful in understanding 802.3ad/LACP.
  • All frames associated with a given “conversation” are transmitted on the same link to prevent mis-ordering of frames. So what is a “conversation”? A “conversation” is the TCP connection.
  • The link selection for a conversation is usually done by doing a hash on the MAC addresses (Route based on source MAC hash) or IP address (Route based on IP hash).
  • Link Aggregation achieves high utilisation across multiple links when carrying multiple conversations, and is less efficient with a small number of conversations (and has no improved bandwith with just one).
Link Aggregation applies between two network devices only. Link aggregation can load balance efficiently – but is not particularly efficient or predictable when there are a low number of TCP connections, hence it is not useful when there are only two TCP connections, the Service Console IP address and the VMkernel IP address. Using link aggregation with VMware ESX and Cisco networking requires the use of Route based on IP hash and static LACP/802.3ad.

So how does the VMkernel distribute traffic over the Link Aggregation Group (LAG)?
The VMkernel distributes the load across the Link Aggregation Group by selecting an uplink to the physical network based on the source and destination IP addresses together. Each source / destination IP conversation gets treated as a unique route, and is distributed across the LAG accordingly. Using an IP-based load balancing method allows for a single-NIC virtual machine to possibly utilise more than 1 physical NIC. Returning traffic may come in on a different NIC, so Link Aggregation must be supported on the physical switch.

The diagram below shows what you would want to achieve with vSwitch0 when using a single virtual switch with two network interfaces with two port groups configured for the Service Console networking and the VMkernel networking.


The Service Console uses vmnic0 as the active uplink and vmnic2 as the passive uplink. The VMkernel uses vmnic2 as the active uplink and vmnic0 as the passive uplink. If one of the network interfaces fail or the corresponding physical switch fails or a cable fails, then the portgroup will utilise the standby network interface.




The configuration settings seen within the VI Client are shown in the figures below.

The vSwitch0 configuration
The vSwitch uses Route based on IP hash with both adapters set as active.






The Service Console portgroup configuration

The Service Console port group uses vmnic0 as the active adapter and vmnic2 as the standby adapter and the load balancing policy is set to Route based on virtual port ID. This overrides the configuration inherited by the vSwitch.



The VMkernel portgroup configuration
The VMkernel port group uses vmnic2 as the active adapter and vmnic0 as the standby adapter and the load balancing policy is set to Route based on virtual port ID. This overrides the configuration inherited by the vSwitch.



Network Utilisation
The graph below shows the current utilisation of the network interfaces assigned to vSwitch0, under normal operations only vmnic0 is used because the Service Console traffic uses vmnic0.












Let's see what happens when I initiate a VMotion to the same server.

The VMotion traffic uses the active network interface vmnic2 as expected.

It is obviously apparent that using override active/passive uplinks for the Service Console and VMkernel port groups has significant advantages. By doing this we restrict the VMotion traffic from flooding the Service Console uplink adapter that can be experienced when using an active/active configuration.

Tuesday, 27 May 2008

Until Round Robin is here.. how to Load Balance over Active/Active Paths using scripts

Recently a customer had a few issues with having all VMs using the same path to the LUNs, this was down to putting too many workloads onto servers that were used as a proof of concept. Inadvertently, SAN problems arose so I was asked to checkover the storage.

First a little background on the infrastructure.... a number of rack servers plus a number of blade servers, hooked into two fabrics with IBM SVC as the backend. Each ESX server has two FC HBA, and each fabric switch had two connections to the SVC, therefore each ESX server has four possible paths to the LUNs. The paths were all active as shown on this pic:

As you can see the path policy is currently set to mru, most recently used path policy is best used in an active/passive configuration.



mru:

  • LUNs presented on single Storage Processor at any one time
  • Failover on NOT_READY, ILLEGAL_REQUEST or NO_CONNECT
  • No preferred path policy
  • No failback to preferred path if it returns online after failover
Since, esxcfg-mpath -l shows that we are in fact using active/active, it is best to change the policy to fixed path policy:

  • LUNs presented on multiple Storage Processors at same time
  • Failover over on NO_CONNECT
  • Preferred path policy
  • Failback to preferred path if it returns online after failover
So how do we now go about changing the policies on all our servers? Well we could use VI-Client and change each datastore to use a different path - doing this for 10 datastores per server with 20+ servers? howabout no! The alternative then would be to script it.

The script from Yellow Bricks is of particular use, as for each LUN it finds it uses a different path for each LUN. The script just sets each LUN up to use a preferred path, but obviously for default installations of ESX, you cannot use preferred path when you are using mru policy. So we must change all LUNs to use fixed path policy first.

By re-using the script form Yellow Bricks, I've come up with this:

#!/bin/bash
# vmhbafixedpath.sh Script to rescan vmhbas on ESX 3.5 host
# Written by hugo@vmwire.com
# 21/05/2008 18:20
for PATHS in 2 4 6 8
do
STPATHS=${PATHS}
COUNTER="1"

for LUN in $(esxcfg-mpath -l | grep "has ${STPATHS} paths" | awk '{print $2}')

do
esxcfg-mpath --lun=${LUN} -p fixed
COUNT=`expr ${COUNTER} + 1`
COUNTER=${COUNT}
if [[ ${COUNTER} -gt ${STPATHS} ]]
then
COUNTER="1"
fi
done
done



Then use the script from Yellow Bricks, to set up the preferred paths. Now the changes do not take into effect until the HBAs are rescanned, and the Storage is refreshed. The following script rescans the HBAs

#!/bin/bash
# rescanhbas.sh Script to rescan vmhbas on ESX 3.5 host
# Written by hugo@vmwire.com & nkouts
# 21/05/2008 18:50
# Assumes there is no vmhba0 and max vmhba9

for HBAS in 2 4
do

STHBAS=${HBAS}
COUNTER="1"

for HBA in $(esxcfg-info -w | grep vmhba | awk '{print $3}' | grep -e 'vmhba\+[1-9]' -o)
do
esxcfg-rescan ${HBA}
COUNT=`expr ${COUNTER} + 1`
COUNTER=${COUNT}
if [[ ${COUNTER} -gt ${STHBAS} ]]

then
COUNTER="1"
fi
done
done


And there is no known console based method to refresh the storage subsystem (anyone?) apart from using VI-Client, rebooting the ESX host or restarting the vmware management service:






service mgmt-vmware restart







UPDATE: Use /usr/bin/vmware-vim-cmd to refresh the storage
/usr/bin/vmware-vim-cmd hostsvc/storage/refresh

So now we have the servers using different paths for each datastore.



















It only took a couple of seconds to change the policies on each server using these scripts, obviously using these as part of a build script would be ideal for deployments where you know the SAN configuration.

Tuesday, 20 May 2008

Update: ESX 3.5 on HS21 XM (7995)

IBM came back with a workaround to my problem,....All workarounds have been tested and work.

The workarounds then for anyone running ESX 3.5 Build 64607 on HS21 XM 7995 v1.08 with 2 x quad core CPUs:

1. Use ESXi instead (No service console, hence no PSOD. Also no mouse services in the console needed, hence no PSOD (this is the problem that I was experiencing).

2. Use ESX 3.5 Up 1 Build 82663 (Stable as of 18th April - double check your checksums!)

3. Use ESX 3.5 build 64607 but disable the gpm module, do this by entering the following on the Service Console:

chkconfig gpm off

then reboot the host, obviously you will get a PSOD but reset it and all should be well thereafter.

Tuesday, 5 February 2008

Planning a VMware ESX deployment on IBM BladeCenter H - Part 2

In the previous post I covered the network design for a HS21 with 4 network interfaces. This post will continue with a diagrammatic representation of the interface table.

As described previously, this configuration provides full network fault tolerance on all levels: adapter, port, CAT5, switch bay and core switch.


Put your finger over any individual constituent part, i.e., pNic, interface, bay switch or core switch, to simulate a failure and there will always be an alternative path.

I'm waiting for the customer to decide on whether to include the CFFv daughtercard in this phase of the project, and will update this post with the new design if required.

Next up, environmentals...

Those of you familiar with the HP c-Class blades will probably know that there is a superb tool called the HP BladeSystem PowerSizer 2.9, I've been trying to find an equivalent from IBM, but as yet have not found anything that comes as close. (Any pointers will be appreciated)

Instead I've had to resort to using data obtained from The Edison Group study titled Blade Server Power Study - IBM BladeCenter and HP BladeSystem, Nov 7 2007, document titled "BLL03002USEN.pdf".

The results show, in summary a BladeCenter H chassis with 14 blades on full load will need 14,352.51 BTU/Hr with a peak power consumption of 4,208.80 Watts. Most modern datacenters with good power feeds will be able to accommodate that kind of load. Cooling requirements will be left to the customer to calculate.

Additionally, this single chassis will require 9 rack units and 4 power feeds due to the additional 2900W power supply modules.

Part 2.... Continued..

Thank you Aaron for your help with the power sizer.

Here is the output from the tool (not as nice as HP's offerring by the way)














In the next part... network design for the x3650.

Saturday, 2 February 2008

Planning a VMware ESX deployment on IBM BladeCenter H - Part 1

Well here I am, starting a new project for a new customer at a new datacenter again. This time, its a large retail organisation looking to do the usual, consolidate, virtualise, go green etc etc. They have selected IBM System X and BladeCenter H as the platforms of choice for the new VMware ESX 3 environment. So here we go with the planning....

The BladeCenter H has eight switch bays and two Advanced Management Module (AMM) bays. The two AMM act in much the same way as the Onboard Administrator on HP C Class. There are two for redundancy. Two of the eight switch bays are used for FC Switches, for this project we are using Brocade 4Gb SAN switches.

The other bays are occupied by Cisco GbE Switch Modules.

HS21s are used for the initial phase of the project. These blades can accommodate upto 6 NICs and 2 HBAs, with 2 onboard and the other 4 provided by daughtercards. The customer has elected to use 4 NICs as opposed to the 6 that I normally recommend for ESX implementations. The two extra NICs are provided by the CFFh daughtercard, this daughtercard houses 2 network adapters AND 2 Fibre Channel HBAs.

The table below (from IBM) show the interface to bay mapping.

Since only 4 interfaces are available, teaming and VLANs will have to be used to provide resilience and to separate the SC and VMKernel networks.

I will be teaming Interface 0 (eth0) with Interface 3 (eth3) as opposed to the IBM table (dedicating an adapter to a service), as this will team one onboard port with one daughtercard port. Likewise eth1 will then be teamed with eth2.

* The location of the two Fibre Channel Adapters should be Daughter Card CFF-h, not v as shown in the IBM table.

The following diagram shows the correct mapping.














The table below details the network interconnects.

Interface is the network adapter inside a blade, Location is where the interface is, Chassis Bay is where the interface terminates at the rear of the BladeCenter chassis, pSwitch is the external core switch that the Chassis Bay uplinks to, vSwitch is the ESX virtual switch that the Interface provides an uplink for, vLAN is the ID that is assigned to each Port Group and Service is the type of port group assigned to a vSwitch.